Home | Sitemap | imprint  
     
       
       
 
 

system dw - al

application

double wall pressure-tight exhaust pipe system (SS) for condensing furnaces in negative and positive pressure, for moist operation mode

 

combustible

oil, gas

 

working temperature

≤ 200°C

 

material

inside: 1.4571 / 1.4404
outside:1.4301

 

wall thickness

inside: 0,6 - 1,0 mm

outside: 0,6 - 1,0 mm

 

welding seam

TIG continuous

 

insulation

mineral insulation with 32.5 or 50 mm wall thickness, bulk density 120 kg/m³

 

tightness

plug connector male / female coupler with interior and exterior special gasket and external locking band

 

admissible for pos. pressure

yes

 

soot fire resistant

no

 

free-standing extension

3 m

 

average roughness

1,0 mm

 

thermal resistance

0,501 m² K/W

 

CE mark number

0036 CPD 9174 001

 

CE classifications

T200 - N1 - W - V2 - L50060 - O00
T200 - P1 - W - V2 - L50060 - O00

Downloads

dw-eco-al_June-2010.pdf

060607_je_Auftragsliste_dw-al_70bc56.pdf

   
           
         
 
© 2010 Jeremias GmbH   